Use check boxes when steps are completed.
Leviton ceiling mount occupancy sensor manual.
Occupancy sensor lighting control ceiling mounted multi technology 24vdc 35ma power consumption 1000 sq ft 360 degree major motion.
Leviton s ceiling mount occupancy sensor offers users a smart way to save energy in larger spaces up to 1 000 square feet in area.
Oscø5 r osc1ø r osc2ø r to be used with 24vac vdc ospxx series and cn100 power pack or other class 2 power supplies.
Leviton offers a wide selection of occupancy sensors and vacancy sensors commonly referred to as motion sensors or motion detectors or motion light sensors for commercial and residential applications.
Installing your occupancy sensor note.
Clean outer surface with a damp cloth only.
Self contained pir ceiling mount occupancy sensor basic operation the odc0s i uses passive infrared pir detection technology to monitor a room for occupancy through a segmented fresnel lens.
Do not touch the surface of the lens.
When a person passes into or out of a sensor zone the sensor detects motion.
Passive infrared 360 degree time adjustment 20s 15m 120v cec title 20 24 compliant.
Clean outer surface with a damp cloth only.
Using both passive infrared pir and ultrasonic u s detection technologies the osc10 m0w occupancy sensor is perfect for areas such as cafeterias classrooms warehouses offices with cubicles and more.
The leviton provolt series combine line voltage occupancy sensors and photocells into a self contained unit.
All sensors must be mounted at least 6 feet away from air vents.
This specialized lens divides the field of view into sensor zones.
The integrated design alleviates the need for separate power pack and occupancy sensor wiring making it a low cost efficient energy solution for new construction and retrofits.
Leviton offers a wide selection of ceiling mount occupancy sensors and vacancy sensors commonly referred to as motion sensors or motion detectors or motion light sensors for commercial and residential applications.
From wall and ceiling mount to wall switch and wireless leviton motion sensors enhance.
Do not mount sensors closer than 10 feet from each other.
Occupancy sensor 8 10 ceiling mount self contained.
34 lx17 w red led pir green led u s auto adapting walk through time delay 30s 30m test mode 6s time delay for 15m with auto exit connect gray wire for photocell ambient light hold off 360.
Do not touch the surface of the lens.
Multi technology ceiling mounted occupancy sensor cat.
All sensors must be mounted at least 6 feet away from air vents.
Step 3 cont d mounting option diagram a occupancy sensor mounted to drop ceiling using threaded rod low voltage wires.
These state of the art devices use passive infrared ultrasonic or a combined multi sensing technology.
These state of the art devices use passive infrared ultrasonic or a combined multi sensing technology.